GPP-3060/6030 User Manual
184
Command
:STATus:PRESet
Function
Clears the operation event enable registers, the
measurement event enable registers and the
questionable event register, The unit will then
return to the default settings status.
Example
:STATus:PRESet
Command
:STATus:OPERation[:EVENt]?
Function
Read the operation event register.
Example
:STATus:OPERation?
Reads the operation event register.
Command
:STATus:OPERation:CONDition?
Function
Read the operation condition status register.
Example
:STATus:OPERation:CONDition?
Read the contents of the operation condition
status register.
Command
:STATus:OPERation:ENABle <NRf>
Function
Programs the operation enable status register.
Description
<NRf>
8: CL (Current enable bit).
16: CLT (Current limit tripped enable
bit).
64: PSS (Power supply shutdown
enable bit).
Example
:STATus:OPERation:ENABle 64
Enable the power supply shutdown bit.
Command
:STATus:OPERation:ENABle?
Function
Read the operation enable status register.