REMOTE CONTROL
185
Example
:STATus:OPERation:ENABle?
Read the contents of the operation enable status
register.
Command
:STATus:MEASurement[:EVENt]?
Function
Reads the measurement event status register.
Example
:STATus:MEASurement?
Reads the contents of the measurement event
status register.
Command
:STATus:MEASurement:ENABle <NRf>
Function
Program the measurement enable status register.
Description
<NRf>
8: ROF (reading overflow enable bit).
16: PTT (pulse trigger timeout enable
bit).
32: RAV (Reading available enable bit).
512: Buffer full enable bit. The register
is 16 bits. If <value> is between 512 and
1,023, it is certainly valid. If <value> is
between 1,024 and 65,535, ensure Cal
(bit8) is a valid value for it to work.
Example
:STATus:MEASurement:ENABle 8
Enables the ROF bit.

Table of Contents