PEL-3000(H) User Manual
236
*4 When the input voltage is varied from 1.5V(5V) to 150V(800V) at a current of
rated power/150V(800V)
*5 Measurement frequency bandwidth: 10Hz to 1MHz
*6 Measurement frequency bandwidth: 10Hz to 20MHz
*7 At measurement current of 100A
CR Mode
Model
PEL-3021(H)
PEL-3041(H)
PEL-3111(H)
Operating Range
*1
H Range
23.3336S-400µS
(42.857m-2.5k)
/(H)1.75S~30µS
(571mΩ~33.3kΩ)
46.6672S-800µS
(21.428m-1.25k)
/(H)3.5S~6S
(285mΩ~16.6kΩ)
140.0016S-2.4mS
(7.1427m
-416.6667)
/(H)10.5S~200µS
(95.2mΩ~5kΩ)
M Range
2.33336S-40µS
(428.566m-25k)
/(H)175mS~3µS
(5.71Ω~333MΩ)
4.6667S-80µS
(214.28m-12.5k)
/(H)35mS~6µS
(2.85mΩ~166kΩ)
14.0001S-242.4µS
(71.427m-
4.16667k)
/(H)1.05S~2S
(952mΩ~50kΩ)
L Range
0.233336S-4µS
(4.28566-250k)
/(H)17.5mS~0.3µS
(57.1Ω~3.33MΩ)
0.46667S-8µS
(2.1428-125k)
/(H)35mS~0.6µS
(28.5Ω~1.66kΩ)
1.40001S-24.24µS
(714.27m
-41.6667k)
/(H)105mS~2µS
(9.52Ω~500kΩ)
Setting Range
H Range
24.5S-0S
(40.8163 m-OPEN)
/(H) 1.75S~30uS
(571m~33.3k)
49.0S-0 S
(20.408 m-OPEN)
/(H) 3.5S~60uS
(285m~16.6k)
147.000S-0S
(6.8027 m-OPEN)
/(H) 10.5S~180uS
(95.2m~5.55k)
M Range
2.45S-0S
(408.1633m-
OPEN)/(H)
175mS~3uS
(5.71~333k)
4.90S-0S
(204.08m-OPEN)
/(H) 350mS~6uS
(2.85mv~166k)
14.70000S-0S
(68.0272m-OPEN)
/(H) 1.05S~18uS
(952m~55.5k)
L Range
0.245S-0S
(4.08163-OPEN)
/(H) 17.5mS~0.3uS
(57.1~3.33M)
0.490S-0S
(2.0408-OPEN)
/(H) 35mS~0.6uS
(28.5~1.66M)
1.4000S-0S
(680.2721m-
OPEN)/(H)
105mS~1.8uS
(9.52~555k)
Resolution
H Range
400µS(30µS)
800µS(60µS)
2.4mS(180µS)
M Range
40µS(3µS)
80µS(6µS)
240µS(18µS)
L Range
S(0.3µS)
S(0.6µS)
24µS(1.8µS)

Table of Contents

Other manuals for GW Instek PEL-3111

Related product manuals