EasyManua.ls Logo

GW Instek PEL-3111 - CV, +CV Mode Response Speed

GW Instek PEL-3111
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PEL-3000(H) User Manual
70
CV, +CV Mode Response Speed
Description
The response speed setting is the response speed
for the negative feedback control of the load
current when used in CV, +CV mode. Response
speed settings are only applicable to CV, +CV
mode.
A response speed that is too fast could cause
the unit to be unstable.
Reducing the response speed can improve
stability.
Operation
1. Make sure the load is off.
2. Press
Main
. Make sure the unit is in CV
mode by using the Mode[F1] soft-key.
3. Select the response speed with the Response[F4]
soft-key.
Range:
Slow, Fast (Fast, 6, 5, 4, 3, 2, 1, slow)
CV mode: The response speed settings
Fast, 6, 5, 4 are all the same
for CV mode.
+CV mode: The response speed settings
5 and 4 are the same for CV
mode. The response speed
settings Slow and 1 is the
same.

Table of Contents

Other manuals for GW Instek PEL-3111

Related product manuals