Part Numbering
Sultan Acoustic Wave Series
49
Sultan Remote Transducer 3” and 3.5”
Model
AWRT Acoustic Wave Remote Transducer
Transducer Frequency
30 30kHz for applications up to 15m for 3” (Cone required1)
20 20kHz for applications up to 20m, 3” only (Cone required1)
15 15kHz for applications up to 30m, 3” only (Cone required1)
10 10kHz for applications up to 40m, 3.5” only (Cone required1)
09 9kHz Positioning / Position Slave applications up to 180m (Cone required1)
05 5kHz for applications up to 60m, 3.5” only (Cone required1)
04 4kHz Positioning / Position Slave applications up to 180m (Cone required1)
Process Temperature - Facing material selection
S Polyolefin 80°C (176°F)
T Teflon 80°C (176°F)
Y Titanium 80°C (176°F)
Transducer Housing Material
4 Polypropylene
Back Cap Mounting Thread Standards
X Not Required (Standard Flange Mount)
TB BSP
Back Cap Mounting Thread Sizes
X Not Required (Standard Flange Mount)
30 3” BSP
50 3.5” BSP
Approval Standard
X Not Required
i0 IECEx Zone 0 Ex ia IIA T4 IP67 Tamb -20°C to 70°C
A0 ATEX Grp II Cat 1 GD IP67 EEx ia IIA T4
i1 IECEx Zone 1 Ex mb II IP68 T5(Tamb -20°C to 65°C) T6(Tamb -20°C to 50°C)
A1 ATEX Grp II Cat 2 GD EEx m II IP68 T5(Tamb -20°C to 65°C) T6(Tamb -20°C to 50°C)
i20 IECEx Zone 20 DIP A20 TA85C IP68 Tamb -20°C to 75°C
A20 ATEX Grp II Cat 1 D T85°C IP67 Tamb -20°C to 75°C
A22 ATEX Dust (Grp II Cat 3 D T85C IP67)
GP CSA Equip Class 2; Pollution deg 2; Tamb -20°C to 75°C (Ordinary Locations)
RN CSA Class I; Div 1/2; Group D; Zone 0; AEx / Ex ia IIA; T4
KN CSA Class II; Div 2; Group F&G; Class III; T6 T85 for Tamb -20°C to 75°C
QN CSA Class II; Div 1; Group E, F&G; Ex mb II; T5(T100) for Tamb -20°C to 65°C;
T6(T85) for Tamb -20°C to 50°C
Connection
C IP68 Sealed unit with cable
Cable Length
6 6m cable
15 15m cable
30 30m cable
50 50m cable
Mounting Accessories
X Not Required
CS End Cap Cable Suspension
Software Options
X Not Required
FP Fast Pulsing
PS Position Slave (Requires Position Slave Amplifier)
AWRT 10 T 4 X X X C 6 X X