CANHEAD enhancements
CANHEAD A01185_11_X00_00 HBM: public 75
Delay time compensation is set under “Delay" in 1/600 second steps = 1.66
ms. The correct setting is:
S at 250 kBaud: 2 x module count + 1
S at 500 kBaud: 1 x module count + 1
“Module count" is the number of assigned CANHEADs or the “Minimum num
ber of CANHEADs" assigned in MGCplus, which is greater than the number of
modules.
This setting is also permanently stored in ML801B, but only becomes active if
the “Bessel CANH" filter type is selected. When the setting is changed, the fil
ter must be modified once again, e.g. type or frequency.