Startup
PMX A4354-2.2 HBM: public 151
11.8 Signal runtimes
Typical signal runtimes of the individual PMX hardware
and software components.
PX878
Dig. input
0.18 ms
PX455
0.34 ms
PX401
0.43 ms
Filter
See
Tab. 11.1
Filter
See
Tab. 11.2
Calculated
channel
0.0 ms
Data
Transfer
See
Tab. 11.3
Limit
Switch /
Dig.
Output
< 0.3 ms
PX878
Dig. output
0.08 ms
PROFINET
EtherCATĀ®
EtherNet/IP
PX878
Analog
output
0.17 ms
Firmware
Hardware
Hardware
PX460
0.32 ms at 19,200 /s
0.16 ms at 38,400/s
Fig. 11.1 Signal runtimes