3 Installation of the drive set
CargoPower installation and operation, revision - 01 8
3.1.2 Installation location and position of the controller box, cable routing
To increase operational safety, controller boxes should always be mounted in positions
that are as well protected as possible from rain or splash water. The controller box must
not be permanently exposed to splashing or gushing water. Installation locations such as
wheel housings or similar are not suitable.
The horizontal installation position of the controller box is not critical. If the controller
box is installed in an upright position, it must be oriented in such a way that the exiting
cables do not point upwards, but downwards or sideways.
If possible, do not lead cables coming out of the controller box upwards, but downwards,
so that any water flowing along the cables does not flow to the controller box.