Maintenance
34
5
f Turn the drum 5 past the point of indexing resistance
and remove the cable-tie residues.
f Close the left and right service flaps.
f Switch the power pack ON.
f Close the gate.
f Load a new cable tie bandoleer, à"Loading cable ties"
on page11.
10.4.2 Changing back-up battery
DANGER
A hazardous electrical current flows though the body
in direct or indirect contact with electrically live parts.
Electric shock, burns or death can result.
f Work on the electrical supply and on parts that are live
when the device is in operation should always be carried
out by a trained electrician.
f Use only OEM fuses of the specified amperage.
f Have faulty electrical components replaced immediately.
f Always disconnect the plug from the power-supply outlet
before starting maintenance work and troubleshooting.
f Check the electrical equipment of the device at regular
intervals. Have defects such as loose connections or
scorched wiring repaired immediately.
f Switch the power pack OFF.
f Disconnect the power cord from the power-supply
outlet.
Data Signal Power
Power pack CPK
2
1
1
f Remove the cover screws 1 .
f Remove housing
2 from the power pack.
3
f Change back-up battery 3 .
For details of battery type, à"PowerpackCPK" on
page38
f Position the housing 2 and ax using the cover
screws 1 .
f Set the date and time, à"Date / time" on page16.
11 Maintenance
11.1 Important notes
Regular servicing is essential in order to ensure that the
device remains in safe working order, à"Maintenance
schedule" on page35.
CAUTION
Crush hazard when jaws close.
f Do not insert fingers between upper and lower jaws and
do not keep your finger on the trigger.
f Always keep the power pack switched OFF while
maintenance is in progress.
CAUTION
Crush hazard due to moving/rotating parts when service flaps
are open.
f Do not insert fingers underneath the drum and do not
keep your finger on the trigger.
f Always keep the power pack switched OFF while
maintenance is in progress.
11.2 Accessories and extras
Accessories and extras can be ordered directly from your
national HellermannTyton representative, àseparate
spare parts list.
Name Article number
Power pack CPK 106-00100
Bench mount kit CPK 106-00040
Overhead suspension CPK 106-00050
CPK safety warnings 106-29003
Power cable, 1.8m 123-90040
Connecting cable, 2m 123-90052

Table of Contents