OperationalNon-OperationalSpecification
1°C per 300m above 950m1°C per 300m above 12000mTemperature De-rating
8-85% Non-Condensing8-95% Non-CondensingRelative Humidity
30% per hour maximum30% per hour maximumRelative Humidity Gradient
950m to 3048m950m to 12000mAltitude
Table 2: Electrical Specifications
ValueSpecification
~1980W (for one second)Max Power Consumption
~1800WTypical Power Consumption
200-240VACInput Voltage
C14PSU Connector Type
AC line inrush current shall not exceed 30A peak,
for up to one-quarter of the AC cycle, after which,
Inrush Current Maximum (per PSU)
the input current should be no more than the
specified maximum input current.
80 Plus
™
PlatinumPSU Efficiency
Table 3: Mechanical Specifications
OperationalNon-OperationalSpecification
10G - 5 ms duration; 5 shocks
positive and 5 negative in each of
3 axes, 30 total shocks.
35G - 136 in/sec trapezoid waveShock
0.278G - Random 5-500 Hz 30
minutes per axis, 3 axes (X, Y, Z)
1.04G - 2~200Hz, 15
minutes/faces, six product faces
Vibration
43 kg / 94.8 lbsWeight
48.4 kg / 106.8 lbsWeight w/ Rails
W: 446.4 mm x L: 825 mm x H: 87.6 mm / W: 17.58in. x L: 32.5in. x
H: 3.4in.
Dimension
482.6 mm / 19 in.Required Rack Width
See EIA-310 Rack StandardRequired Rack Depth
2URack Units (U)
Table 4: Data Capacity Specifications
ValueSpecification
24Number of Drive Slots
184.32 TBMax Raw Data Storage Capacity
15
1 Ultrastar Serv24-HA Overview
User Guide 1.3 Ultrastar Serv24-HA Specification Summary