6.
Set Filtering Time.
Within the set ltering me, the same target will not trigger the alarm repeatedly.
7.
Select the target types in Detecon Target.
Only selected target types trigger linkage and alarm.
8.
Click Save.
What to do next
Set the arming schedule and linkage and alarm. See
Set Arming Schedule and ITS Linkage and
Alarm for details.
Set Congeson Detecon
The device detects trac congeson in the detecon area and captures pictures.
Before You Start
Set detecon areas. See Set Polygon Area and Set Lane Area for details.
Steps
1.
Go to VCA → Set
Applicaon → Tunnel Event Detecon → Panoramic Rule Sengs .
2.
Click Add Event and select Congeson Detecon.
3.
Select Arming Lane or Arming Polygon.
Congeson detecon takes eect in the selected lanes or areas.
4.
Set Sensivity.
With higher
sensivity, the device is more sensive to detect and recognize targets.
5.
Set Duraon.
When the
congeson in the detecon area lasts longer than the duraon, an alarm is triggered.
6.
Set Filtering Time.
Within the set
ltering me, the congeson in the same detecon area will not trigger the alarm
repeatedly.
7.
Click Save.
What to do next
Set the arming schedule and linkage and alarm. See
Set Arming Schedule and ITS Linkage and
Alarm for details.
Set Roadblock
Detecon
The device detects roadblocks in the detecon area and captures pictures.
Before You Start
Set detecon scenes and detecon areas. See Set Detecon Scene , Set Polygon Area and Set Lane
Area for details.
TandemVu PTZ Camera User Manual
29