Fingerprint Access Control Terminal
46
Steps:
1. In the editing interface, click the Door_1 button to edit the information of the selected door.
1) Door Magnetic: The Door Magnetic is in the status of Remain Closed (excluding special
conditions).
2) Exit Button Type: The Exit Button Type is in the status of Remain Open (excluding special
conditions).
3) Door Locked Time(s): After swiping the normal card and relay action, the timer for locking the
door starts working.
4) Door Open for Disabled Person: The door magnetic can be enabled with appropriate delay after
disabled person swipes the card.
5) Door Open Timeout(s): The alarm can be triggered if the door has not been close
6) Enable Lock Door when Door Close: This function has not been supported yet.
7) Duress Code: The door can open by inputting the duress code when there is a duress. At the
same time, the access system can report the duress event.
8) Super Password: The specific person can open the door by inputting the super password.
2. Click the Restore Default Value to restore all parameters into default settings.
3. Click the Edit button to save parameters.
4. Click the Hardware Parameters Downloading button to download the updated parameters to the
local memory of the device.
Note: The attendance device does not support the function.