Fingerprint Access Control Terminal
73
Alarm Output: The alarm output will be triggered for notification.
Door: The door status of open, close, normally open, and normally close will be triggered.
6. Click the button to save parameters.
7. Click the Apply button to download the updated parameters to the local memory of the device.
Notes:
The door status of open, close, normally open, and normally close cannot be triggered at the
same time.
The attendance device does not support opening door, closing door and capturing.
Card Linkage
In the Event Interact interface, the linkage alarm action, after triggering the card number, can be set.
Steps:
1. Click the Card Event Interact tab to enter the event card interface
2. Select the host to be set from the host list.
3. Click the button to start setting the event linkage.
4. Click the radio button of card linkage, and input the card number.
5. Select the event source, and check the checkbox of the card reader’s serial number.
6. Set the linkage target, and set the property as Trigger to enable this function.
Controller Buzzer: The audible warning of controller will be triggered.
Snapshot: The real-time capture will be triggered.
Reader Buzzer: The audible warning of card reader will be triggered.
Alarm Output: The alarm output will be triggered for notification.
Door: The door status of open, close, normally open, and normally close will be triggered.
7. Click the button to save parameters.
8. Click the Apply button to download the updated parameters to the local memory of the device.
Note: The door status of open, close, normally open, and normally close cannot be triggered at the same
time.