4.3 Minimum Frequency Setting
53
1
2
3
4
5
6
7
8
9
10
11
Power On Options
Sets the minimum frequency for frequency measurement.
The setting of the minimum frequency determines the
sampling time (gate time) used in low frequency mea-
surement.
<Example>
Minimum frequency 0.5 Hz
Sampling time 2 s
4.3 Minimum Frequency Setting
34
1. In order to display the Power On
Option setting screen, hold dow
n
the
SHIFT
key while turning th
e
function switch.
2. Press the
HOLD
key 6 times to di
s-
play the Minimum Frequency se
t-
ting screen.
3. Press the
RANGE
key or the
DUA
L
key to select the minimum fr
e-
quency setting.
4. Confirm the selection by pressin
g
the
Hz
key.
5. Hold down the
SHIFT
key to ent
er
the measurement screen.
Otherwise, turn the function switc
h
to OFF to finish setup.
0.5 Hz (default)
/ 1 Hz
/ 2 Hz
/ 5 Hz
1
SHIFT +
Power On
2
(6 times)
5