Configuration and management
164
4.9
Named loopback addresses
BAT54-Rail/F..
Release
7.54
06/08
D Connections: Messages about establishment and termination of con-
nections and any errors that occurred (display trace)
D Accounting: Accounting information stored after termination of a con-
nection (user, online time, transfer volumes)
D Administration: Messages on changes to the configuration, remotely
executed commands, etc.
D Router: Regular statistics about the most frequently used services
(breakdown per port number) and messages about filtered packets,
routing errors, etc.
D Priority
D Alert: This is a collection of messages of interest to the administrator
(general SYSLOG priority: PANIC, ALERT, CRIT).
D Error: At this level all error messages which can occur under normal
conditions are communicated; no special attention is required by the
administrator, e.g. connection errors (general SYSLOG priority:
ERROR).
D Warning: This level communicates messages which do not compro-
mise normal operating conditions (general SYSLOG priority: WARN-
ING).
D Information: At this level, all messages are sent that have a purely
informational character (e.g. accounting) (general SYSLOG priority:
NOTICE, INFORM).
D Debug: Communication of all debug messages. Debug messages
generate large data volumes and can compromise the device's oper-
ation. For this reason they should be disabled for normal operations
and only used for trouble-shooting (general SYSLOG priority:
DEBUG).