22
Installation DRAGON MACH4000
Release
01
07/2018
1.4 Signal contact
Figure 7: Signal contact: 3-pin terminal block with screw lock; position on the device
(rear side of the device)
The signal contact is a potential-free changeover contact. If the device is not
connected to a power supply, the changeover contact (2) is connected to the
normally closed contact (1) (see figure 7).
The signal contact allows you to control external devices or monitor device
functions.
In the configuration, you specify how the device uses the signal contact.
You find detailed information regarding possible applications and
configuration of the signal contact in the software user documentation on the
Hirschmann product pages (www.hirschmann.com).
1.5 Ethernet ports
You can connect end devices and other segments to the device and media
module ports using twisted pair cables or optical fibers (F/O).
1.5.1 1/2.5/10 Gbit/s F/O port
This port is an SFP slot.
The port allows you to connect network components according to the
IEEE 802.3 (Clause 49) 10GBASE-R standard.
The port allows you to connect network components according to
IEEE P802.3bz 2.5 Gbit/s.
123