EasyManua.ls Logo

Hirschmann DRAGON MACH4000 series - Power Supply Unit Module; Fan Module; Media Modules

Hirschmann DRAGON MACH4000 series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation DRAGON MACH4000
Release
01
07/2018
61
7.1.2 Power supply unit module
7.1.3 Fan module
7.1.4 Media modules
Dimensions See “Dimension drawings” on page 62.
Weight 30 oz (850 g)
Mounting of the
power supply
modules
Tightening torque 4.4 lb-in (0.5 Nm)
Mounting of the
cover panel
Tightening torque 4.4 lb-in (0.5 Nm)
Power supply
unit
Rated voltage range 100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Voltage range including
maximum tolerances
90 V AC ... 264 V AC, 47 Hz ... 63 Hz
Power loss buffer > 21 ms at 100 V AC
> 19 ms at 240 V AC
Overload current protection at
input
Non-replaceable fuse
Peak inrush current < 20 A (6 ms)
Current integral I²t 1.8 A²s
Crest factor < 4
Dimensions See “Dimension drawings” on page 62.
Weight 26.46 oz (750 g)
Mounting a fan
module
Tightening torque 4.4 lb-in (0.5 Nm)
Fan module Noise emission < 50 dB
Dimensions See “Dimension drawings” on page 62.
Weight D4K-12TP-RJ45 20.90 oz (650 g)
D4K-12SFP 24.69 oz (700 g)
Installing the media
modules
Tightening torque 4.4 lb-in
(0.5 Nm)
Mounting of the cover
panel
Tightening torque 4.4 lb-in
(0.5 Nm)
Climatic conditions
during operation
Ambient temperature +32 °F ... +140 °F (0 °C ... +60 °C)
a
a. Hirschmann recommends to use SFP transceivers with “EEC” extension.
Humidity 10 % ... 95 %
(non-condensing)
Air pressure min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (1312 ft; 400 m)
Climatic conditions
during storage
Ambient temperature 40 °F ... +158 °F (40 °C ... +70 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (1312 ft; 400 m)
Pollution degree 2
Protection classes Laser protection Class 1 in compliance with IEC 60825-1

Table of Contents