52
Installation DRAGON MACH4000
Release
01
07/2018
3 Making basic settings
Note: Two or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
V.24 connection (Command Line Interface)
HiDiscovery protocol using the HiDiscovery or Industrial HiVision
application
a
BOOTP
a
DHCP
a
DHCP Option 82
a
AutoConfiguration Adapter
Default settings
IP address: The device looks for the IP address using DHCP
a
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Basic device:
Optical 10 Gbit/s ports: 10 Gbit/s full duplex
Autonegotiation deactivated.
Media module D4K-12TP-RJ45:
10/100/1000 Mbit/s ports: 10/100/1000 Mbit/s full duplex
Autonegotiation activated.
Media module D4K-12SFP:
Optical 100/1000 Mbit/s ports: 100/1000 Mbit/s full duplex
Autonegotiation exclusively activated for 1000 Mbit/s.
Out-of-band management port:
Default IP address: 192.168.1.1 / 255.255.255.0
a. Out-of-band management port excluded