EasyManua.ls Logo

Hirschmann DRAGON MACH4000 series - 3 Making Basic Settings

Hirschmann DRAGON MACH4000 series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52
Installation DRAGON MACH4000
Release
01
07/2018
3 Making basic settings
Note: Two or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
V.24 connection (Command Line Interface)
HiDiscovery protocol using the HiDiscovery or Industrial HiVision
application
a
BOOTP
a
DHCP
a
DHCP Option 82
a
AutoConfiguration Adapter
Default settings
IP address: The device looks for the IP address using DHCP
a
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Basic device:
Optical 10 Gbit/s ports: 10 Gbit/s full duplex
Autonegotiation deactivated.
Media module D4K-12TP-RJ45:
10/100/1000 Mbit/s ports: 10/100/1000 Mbit/s full duplex
Autonegotiation activated.
Media module D4K-12SFP:
Optical 100/1000 Mbit/s ports: 100/1000 Mbit/s full duplex
Autonegotiation exclusively activated for 1000 Mbit/s.
Out-of-band management port:
Default IP address: 192.168.1.1 / 255.255.255.0
a. Out-of-band management port excluded

Table of Contents