7.3 EMC and immunity
EMC interference emission Standard applications Railway applications (trackside)
EN 55032 Class A Fulfilled Fulfilled
FCC 47 CFR Part 15 Class A Fulfilled Fulfilled
EN 61000-6-4 Fulfilled Fulfilled
EMC interference immunity Standard applications
a
a. According to EN 61000-6-2.
Railway applications (trackside)
b
b. According to EN 50121-4.
Electrostatic discharge
EN 61000-4-2 Contact discharge ±4 kV ±6 kV
EN 61000-4-2 Air discharge ±8 kV ±8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 3000 MHz 10 V/m 20 V/m
Fast transients (burst)
EN 61000-4-4 Supply voltage connection ±2 kV ±2 kV
EN 61000-4-4 Data line ±4 kV ±2 kV
Voltage surges - AC supply connection
EN 61000-4-5 line/ground ±2 kV ±2 kV
EN 61000-4-5 line/line ±1 kV ±1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ±1 kV ±2 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V 10 V
Stability Standard applications Railway applications (trackside)
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 0.14 in. (3.5 mm) amplitude —
8.4 Hz ... 150 Hz with 1 g —
IEC 60068-2-27, test Ea Shock 15 g at 11 ms —