MACH4000
Dimensions See “Dimension drawings” on page 62.
Weight 16.09 lb (7.3 kg)
Power supply Rated voltage range 100 V AC ... 240 V AC, 50 Hz ... 60 Hz
Back-up fuse for each
voltage input
Nominal rating:
Characteristic:
6.3 A
slow blow
Connection type Built-in non-heating device plug (C14 plug
according to IEC 60320-1)
min. conductor
diameter
AWG18 (0.75 mm²)
max. conductor
diameter
AWG12 (2.5 mm²)
Grounding the device Tightening torque
Protective grounding
4.4 lb-in (0.5 Nm)
Signal contact Nominal value I
max
=2A at U
max
= 230 V AC
I
max
=2A at U
max
=30VDC
Connection type 3-pin terminal block
Tightening torque 4.4 lb-in (0.5 Nm)
min. conductor
diameter
AWG18 (0.75 mm²)
max. conductor
diameter
AWG16 (1.3 mm²)
Climatic conditions
during operation
Ambient air
temperature
a
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
+32 °F ... +140 °F (0 °C ... +60 °C)
b
b. Hirschmann recommends to use SFP transceivers with “EEC” extension.
Humidity 10 % ... 95 %
(non-condensing)
Air pressure min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (1312 ft; 400 m)
Climatic conditions
during storage
Ambient air
temperature
c
c. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
40 °F ... +158 °F (40 °C ... +70 °C)
Humidity 5 % ... 95 %
(non-condensing)
Air pressure min. 795 hPa (+6562 ft; +2000 m)
max. 1060 hPa (1312 ft; 400 m)
Pollution degree 2
Protection classes Laser protection Class 1 in compliance with IEC 60825-1
Degree of protection IP20