EasyManua.ls Logo

Hirschmann DRAGON MACH4000 series - Display Elements; Device State

Hirschmann DRAGON MACH4000 series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Installation DRAGON MACH4000
Release
01
07/2018
1.7 Display elements
After the supply voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up.
1.7.1 Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Figure 9: Device status: location of the display elements on the device (front side of
the device)
LED Display Color Activity Meaning
STAT Device Status none Device is starting and/or is not ready for
operation.
green lights up Device is ready for operation.
Characteristics can be configured
red lights up Device is ready for operation.
Device has detected at least one error in
the monitoring results
flashes 1 time
a period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
flashes 4 times
a period
Device has detected a multiple IP address
ACA Storage medium
ACA22
ACA31
none ACA storage medium not connected
green lights up ACA storage medium connected
flashes 3 times
a period
Device writes to/reads from the storage
medium
yellow lights up ACA storage medium inoperative
FANACA RM
PP1P2
STAT
1

Table of Contents

Related product manuals