Installation DRAGON MACH4000
Release
01
07/2018
27
RM Ring Manager — none No redundancy configured
green lights up Redundancy exists
flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow lights up No redundancy exists
FAN Fan module — none No fan module present
green lights up All individual fans of the fan module are
operational.
yellow lights up At least one individual fan of the fan
module is not operational.
P Supply voltage — none Supply voltage is too low
yellow lights up Supply voltage 1 or 2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
green lights up Supply voltage 1 and 2 is on
P1 Supply voltage — none At least one of the following cases
applies:
Power supply unit is not connected to
slot P1.
There is no external supply voltage or
it is too low.
No internal supply voltage.
green lights up
Power supply unit is connected to slot
P1.
Boot procedure started
Valid supply voltage connected.
P2 Supply voltage — none At least one of the following cases
applies:
Power supply unit is not connected to
slot P2.
There is no external supply voltage or
it is too low.
No internal supply voltage.
green lights up
Power supply unit is connected to slot
P2.
Boot procedure started
Valid supply voltage connected.
1 No function in the
existing device
version.
LED Display Color Activity Meaning