Installation DRAGON MACH4000
Release
01
07/2018
9
The device may overheat if the fan module fails or is removed. Switch
off the device or replace the fan module within 2 minutes, otherwise
failures or damage to the device may occur.
After removing the fan module during active operation, the individual
fans continue to spin for a few seconds. Do not touch rotating fan
blades. Do not insert objects into rotating fan blades.
Installation site requirements
Operate the device at the specified ambient temperature (temperature of
the ambient air at a distance of 2 inches (5 cm) from the device) and at
the specified relative humidity exclusively.
When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.