HIRSCHMANN MCS
Error Code Description Solution
Kinematic Errors
0A00 – 0AFF
E0A00 Capacity utilization >= 100% Lay down the load. Only operate within allowed parameters
E0A08 Capacity utilization >= 90% Warning: Operating close to Cut-off
E0A20 Shutdown due to overload Lay down the load. Only operate within allowed parameters
E0A21 Overload Warning Warning: Operating close to Cut-off
E0A24 A2B switch Lower the load
E0A33 System Bypass Warning: Load monitoring inactive
E0A35 Bypass A2B switch Warning: Load Lift not monitored