51 USER CODES
This menu is used to program user codes for users 1 to 32.
Each code is required to be 4-6 digits in length. The digit 0 is
not allowed and codes cannot end with the number 9 as this
would conflict with the duress facility
New codes must be verified in order
to be accepted
(as would user codes that
only differed by one digit).
. The system will record a tamper event if a User
Code is entered incorrectly more than 7 times.
52 USER NAMES
User names enable more detailed information to be displayed
in the system log and are also used in the user menus.
53 USER OPTIONS
Each user can be assigned a number of options. These are
explained in detail in below...
57
User Menu
Full set enables the user to fully arm the system using their code.
Unset allows a user to unset the system using their code.
Inhibit allows a user to inhibit zones or tampers using their code.
Allows a user to part set A the system within a user menu (See User Menu below).
Allows a user to part set B the system within a user menu (See User Menu below).
The User Menu is used to generate a menu for the user. When they enter their code it will
pop the user into a menu structure which contains the following items....
Full Used to fully arm the panel
Quick Arm Used to fully arm the panel without an exit time
Part Set A Used to part-set area A of the panel
Part Set B Used to part-set area B of the panel
View User Log Used to enter the View User Log menu
Walk Test Used to enter User Walk Test
Chime On/Off Used to toggle the chime operation
Bell Test Used to do a bell test
Manager Menu Used to enter the manager menu (See Below).
The User Menu provides a more secure way of accessing system functions. By disabling
quick codes and giving the user the User Menu option only authorised users will be able to
access the functions outlined above. The items in the menu are selected using the PREV
and NEXT keys. Press the YES key to enter a menu item.
The manager menu is used to enable a user to change the following panel options...
Set Date & Time Used to set the system date and time
View Eng. Log Used to enter engineer view log
User Codes Used to change a user code
User Options Used to change user options
User Names User to change the name of a user
User Blk Assign Used to assign User Codes to specific blocks
User ProxAssign Used to assign User Codes to specific proximity tags
System Config? Set Eng. Access to YES allows Engineer Code to work
without needing the User Code as well
Once the Manager Menu option has been selected the user will automatically have a User
Menu as this is the only way that the Manager Menu can be accessed.
If set to YES then you need to key-in the User code and use prox tag to UNSET the system
Set
. The internal sirens
will activate when the system goes into Engineer Mode and
can be silenced by pressing any key on the active keypad.
Manager Menu
Code&Prox
User Menu
PartSet B
PartSet A
Inhibit
Unset
Full Set