62 SYSTEM TIMERS
(Mins)
(Mins)
(Mins)
(Secs)
(Secs)
(Secs)
(Days)
(Mins)
(Mins)
(Secs)
This menu is used to program timers in the control panel. To
edit a time select it using the PREV or NEXT keys then press
YES. Enter the new time to be used. The new time will then be
programmed. Most of the timers are self explanatory but there
are a two things to note....
Note 1: Split Entry time is an EN 50131-1 feature. If at the end of the
entry time the system has not been unset it will only activate the internal siren
and the Split Entry time starts. Then at the end of the Split Entry time, if the
system still has not been unset, both internal and external sirens will activate
and a message sent to the monitoring station (usually this message happens
after a further 20 second delay - or 30 seconds in UK).
Note 2: ā€œDbl. Nokā€ is shorthand for Double Knock. Zones with the
Double Knock feature need to be activated twice within the Dbl.Nok Reset
period before they are flagged. Or, they need to remain activated for the
duration of the Dbl.Nok Open period before they are flagged
633 Mains Flt Dly (Mins)
632 Fire Exit Delay (Secs.)
631 Wks 2 Service (Weeks)
63 MISC. TIMERS
Wks 2 Service menu is used to program the number of
weeks between system services. When the service period
expires, Service Due ... Contact Engineer will be displayed,
as a prompt to the user, everytime the system
is unset. Note that programming "00" disables this feature.
Fire Exit Dly; you can delay the effects of opening a fire exit
door by selecting a delay period here (in seconds).
Mains Flt Dly; During a power blackout, a mains fault will
only be reported to a Central Station if it exceeds the mains
fault delay period that is programmed.
Note: Delays SMS and voice reporting also
64 BLOCK TIMERS
This is where you can adjust the Entry Time, Exit Time,
Internal and External Siren Times for each block. A block is a
semi-autonomous alarm system within the overall system.
Timers Menu
61 SET DATE & TIME
Used to set the system date and time. The date follows the
following format dd/mm/yy i.e. Day/ month /year and the time is
in 24Hr format as follows hh:mm i.e. Hours : minutes.
Note: You will be prompted to key-in the time and date when you initially
power-up your system
!
!
!
!
59
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)