Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
*Final Door can be used to terminate arming for clauses 6.4.2 and 6.4.3 but is not strictly necessary as
the Shunt lock zone going closed will terminate arming.
** Ensure that there are no ShuntLock Zone types on the system for Clauses 6.4.4 and 6.4.5
Clause 6.4.2 Clause 6.4.3 Clause 6.4.4 Clause 6.4.5
Police Options – Alarm Confirm Yes Yes Yes Yes
Police Options – Alarm Confirm Time 30 mins 30 mins 30 mins 30 mins
Police Options – Auto Inhibit Yes Yes Yes Yes
Police Options – “Prox Entry” N/A No No Yes
Police Options – “Access/BV” Yes Yes Yes No
Police Options – Engineer Reset Yes Yes Yes Yes
Arming Options – “Final Door” Optional* Optional* Yes Yes
Shunt Lock Zone “Unset” Option Yes No N/A** N/A**
Entry/Exit Zone “Disable BV” Option No No Yes No