Please carry out proper grounding treatment.
Noise filter
Connect the interference filter at an appropriate place to avoid the adverse effect of interference on servo
drive.
The following is an example of wiring considering anti-interference measures.
*1. Please try to use a thick wire of more than 2.0 mm
2
for grounding (flat braided copper wire is more suitable).
*2. Please try to use double stranded wires for connection.
Noise Filter Wiring and Connection Precautions
Please observe the following precautions when wiring and connecting interference filters.
Please separate the input wiring from the output wiring. In addition, do not put the input and output wires into
the same sleeve, nor bind them together.
Operation relay sequence
control loop
User signal generation loop
Earth grounding ... must be special for grounding