Accenta/Optima Engineer’s Manual
31
2 = LED Keypad:
The LED keypad is limited to show the last eight set periods with the eighth being the oldest. Zone, PA and
Tamper indicators will be lit to show zone in alarm . Flashing LED indicates the first zone in alarm. Day indi-
cates the status of the panel at the time of the alarm.
O = Omit Allow and Double Knock
1 = Double Knock
Double knock programming is used when zones are likely to create false activations. Double knock requires
two activations within 10 minutes of the same zone or a zone left open for 10 seconds.
NOTE: It is not advisable to apply Double Knock to magnetic door contacts. Double Knock cannot be
applied to Fire Zones. By default, no zones are in Double Knock mode and all zones are enabled as
Omit Allow.
LCD Keypad:
Programming a Zone as Double Knock
The [up arrow] scrolls through zones.
Press [CHIME] to toggle double knock status on or off.
Press [9] to turn all double knock zones on.
Press [0] to turn all double knock zones off.
Press [CHIME] to enter into Event Log menu. LED’s 1 and 2 are on.
Press [2] for LED keypad. The first zone to activate is indicated by a
flashing LED.
Press [1 to 8] for the desired event or [CHIME] to go through
events in sequence.
Press [RESET] twice to leave the menu.
While in Engineer program mode press [OMIT] or press [up arrow]
until 0>Omit allow & Double Knock is displayed then press [SET].
Press [1] to select Double Knock. The first zone is
displayed with status NO or YES.
Press the [zone number] or [CHIME] to toggle the
status on or off.
Press the [up arrow] or [zone number] to go to the
other zones and follow the same procedure as above.
Press [RESET] twice to leave the menu.
1. Double Knock1. Double Knock
1. Double Knock1. Double Knock
1. Double Knock
2. Omit Allow2. Omit Allow
2. Omit Allow2. Omit Allow
2. Omit Allow
[OMIT]
[1]
[RESET]
Omit Allow &Omit Allow &
Omit Allow &Omit Allow &
Omit Allow &
Double KnockDouble Knock
Double KnockDouble Knock
Double Knock
1: <Zone Name>1: <Zone Name>
1: <Zone Name>1: <Zone Name>
1: <Zone Name>
Double Knock:NODouble Knock:NO
Double Knock:NODouble Knock:NO
Double Knock:NO
1: <Zone Name>1: <Zone Name>
1: <Zone Name>1: <Zone Name>
1: <Zone Name>
Double Knock:YESDouble Knock:YES
Double Knock:YESDouble Knock:YES
Double Knock:YES
[zone number] or [CHIME]
Event Log (cont’d)
12
3
4
5
6
7
8
[CHIME]
[RESET]
12
3
4
5
6
7
8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Accenta Series and is the answer not in the manual?

Honeywell Accenta Series Specifications

General IconGeneral
Zones8
Power Supply230V AC
Battery BackupYes
Tamper ProtectionYes
Communication FormatContact ID, SIA
CommunicationWired
Compatible withHoneywell detectors and accessories
Outputs2