CNI2
O
perating and Installation
Guide
153
ELECTRICAL
-
POWER
Battery Voltage:
(without load applied)
Lithium = 6.9 Volts, Alkaline = 6.0 Volts
A
pproved Battery Pack Assemblies
40
-
5170
Dual cell lithiu
m, disposable configuration.
40
-
3444
-
1
Quad cell lithium, disposable configura
tion.
40
-
3503
-
1
Quad cell a
lkaline molded plastic assembly (replaceable cells).
40
-
2596
-
1
Quad cell alkaline disposable configuration.
Battery Life
Highly dependent upon number of pulse counting inputs, cellular call durations, and the number
of calls m
ade per day or month. Due to the number of potential variables, this is difficult to
predict for all circumstances. Mercury can provide reference information that details a single
“typical” site and the expected life based on this example case.
CAUTI
ON:
Disposal of lithium battery cells is strictly regulated in most areas as hazardous waste material.
Consult your regional waste disposal authority to ensure full compliance with legal statutes
when disposing of cells.
W
ARNING
:
Transport of prim
ary cell lithium batteries (even when fully discharged) is strictly forbidden on
passenger aircraft. Cargo shipment of batteries via UPS, FedEx, etc., requires approved
shipping containers, packing methods, MSDS information, and other paperwork to be incl
uded.
Current Requirements during Transmission
GSM:
During transmission the average current is 300 mA but peak currents can be as high as
2
.0 amps for a duration of 0.5 milliseconds every 4.5 milliseconds.
iDEN:
During transmission the average cur
rent is 250 mA but
peak currents can be as high as
1.2 amps for a duration of 15 milliseconds every 90 milliseconds.
CDMA:
During transmission the maximum curre
nt draw is 800 mA.
Sleep current (data logger mode, no communications option boards)
<
35
0
μA.
Sleep current (transparent modem mode, no communications option boards)
<
300
μA.