106 Xenon/Granit User Guide
The table below shows the results of the Auto Reconnect On and Off settings: 
Maximum Link Attempts
The Maximum Link Attempts setting controls the number of times the scanner 
tries to form a connection with a base. During the connection setup process, the 
scanner transmits in order to search for and connect to a base. In order to prevent 
continuous transmissions that could interfere with other users of the ISM band, 
the number of attempts to connect is limited by this setting. After the maximum 
number of attempts is reached, the scanner will not attempt to reconnect to a base. 
Pressing the trigger or placing the scanner in the base resets the counter and the 
scanner will again try to link. 
Scan the Maximum Link Attempts bar code, then scan the number of attempts for 
the setting (from 0-100) from theProgramming Chart, beginning on page 341, 
then Save. Default = 4.
Note: When Auto Reconnect Mode is On, setting Maximum Link Attempts to zero will cause 
the scanner to try to link until the Power Time-Out Timer setting expires. When Auto 
Reconnect Mode is Off, setting Maximum Link Attempts to zero will cause the 
scanner to only attempt linking one time after a trigger pull.
Event Auto Reconnect On Auto Reconnect Off
Scanner out of range Relink occurs automatically. If 
maximum number of link attempts 
is unsuccessful, then the scanner 
must be relinked by either pulling 
the trigger or placing the scanner 
in the base. (See Maximum Link 
Attempts on page 106.)
The scanner is relinked by 
pulling the trigger.
Base reset (firmware 
upgrade or power cycle)
Scanner behaves as if out of range. No attempt to relink made 
while base is powered off. 
Trigger must be pulled to 
initiate relinking.
Scanner power down due to 
Power Time-Out Timer 
setting 
Trigger must be pulled or the scanner must be placed in the base unit 
to relink.
(Note: scanner relinks on power up, but powers on due to one of the 
above actions.)
Scanner reset due to 
firmware upgrade
Relink occurs automatically.
Scanner reset due to instant 
charge pack change
Relink occurs automatically.
Scanner placed in different 
base unit
Relink to new base occurs automatically.