52 Xenon/Granit User Guide
the button is pressed. The red LED on the base or blue LED on the Access Point will
remain lit to indicate that Page Mode is off. (This light will go out when the button
is pressed, then back on when it’s released.) Default = Page Mode On.
Note: If you are using a Xenon 1902h model, refer to Quiet Operations - LED and Volume
Settings on page 145 for additional Page Button settings.
Page Pitch
When you press the Page button on the base or Access Point, the scanners associ-
ated with that base or Access Point will begin beeping (see Page Button on page
45). You can set the pitch of the paging beep for each scanner by scanning one of
the following bar codes. Default = Low.
Error Indicators
Beeper Pitch - Base Error
Note: This feature only applies to the CCB01-010BT base.
The CCB01-010BT base can be configured to beep at a particular pitch when an
error occurs, such as transmission problems to a host system. The beeper pitch
codes modify the pitch (frequency) of the error tone the base emits when there is
an error. Default = Low.
* Page Mode On
Page Mode Off
* Low (1000 Hz)
Medium (3250 Hz)
High (4200 Hz)