56 Xenon/Granit User Guide
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base or an Access 
Point, scan the Override Locked Scanner bar code below with a new scanner and 
place that scanner in the base, or scan the Access Point linking bar code. The 
locked link will be overridden; the broken or lost scanner’s link with the base or 
Access Point will be removed, and the new scanner will be linked.
Out-of-Range Alarm
If your scanner is out range of the base, an alarm sounds from both your base and 
scanner. If your scanner is out range of an Access Point, an alarm sounds from just 
the scanner. The alarm stops when the scanner is moved closer to the base or 
Access Point, when the base or Access Point connects to another scanner, or when 
the alarm duration expires. To activate the alarm options for the scanner or the 
base and to set the alarm duration, scan the appropriate bar code below and then 
set the time-out duration (from 0-3000 seconds) by scanning digits on the 
Programming Chart, beginning on page 341, then Save. Default = 0 sec (no alarm).
Note: If you are out of range when you scan a bar code, you will receive an error tone even if 
you do not have the alarm set. You receive the error tone since the data could not be 
communicated to the base or Access Point or the host.
Alarm Sound Type
You may change the alarm type for the scanner or a CCB01-010BT base by scan-
ning the appropriate bar code below and then scanning a digit (0-7) bar code from 
the Programming Chart, beginning on page 341, then Save. Default = 0. 
The sounds are as follows:
Override Locked Scanner
(Single Scanner)
Note: The Access Point does not have a base alarm.