190 Xenon/Granit User Guide
Straight 2 of 5 IATA (two-bar start/stop)
<Default All Straight 2 of 5 IATA Settings>
Straight 2 of 5 IATA On/Off
Straight 2 of 5 IATA Redundancy
If you are encountering errors when reading Straight 2 of 5 IATA bar codes, you may
want to adjust the redundancy count. Redundancy adjusts the number of times a
bar code is decoded before transmission, which may reduce the number of errors.
Note that the higher the redundancy count, the longer it will take to decode the bar
code. To adjust the redundancy, scan the Straight 2 of 5 IATA Redundancy bar code
below, then scan a redundancy count between 0 and 10 on the Programming
Chart, beginning on page 341. Then scan the Save bar code. Default = 0.
Straight 2 of 5 IATA Message Length
Scan the bar codes below to change the message length. Refer to Message Length
Description (page 178) for additional information. Minimum and Maximum
lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
On
* Off
Straight 2 of 5 IATA
Redundancy
Minimum Message Length
Maximum Message Length