Xenon/Granit User Guide 119
Trigger Toggle Timeout
This sets the length of time the scanner stays in trigger toggle mode before revert-
ing to scan mode. After scanning the Trigger Toggle Timeout bar code, set the 
time-out duration (from 0 to 65 seconds) by scanning digits from the 
Programming Chart, beginning on page 341, then Save. Default = 5 seconds.
Note: If this is set to 0, you must repeat the toggle sequence to return to the default 
scanning mode. For example, if 2 quick trigger presses puts the scanner into cell 
phone read mode and the Trigger Timing is 0, you would have to do 2 quick presses 
again to go back to the default scanning mode.
Serial Trigger
You can activate the scanner either by pressing the trigger, or using a serial trigger 
command (see Trigger Commands on page 262). You must be in a serial interface 
mode in order to use serial triggering. Refer to RS232 Serial Port (page 16) or USB 
Serial (page 19) for further information. When in serial mode, the scanner scans 
until a bar code has been read or until the deactivate command is sent. The scan-
ner can also be set to turn itself off after a specified time has elapsed (see Read 
Time-Out, which follows).
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when 
using serial commands to trigger the scanner. Once the scanner has timed out, you 
can activate the scanner either by pressing the trigger or using a serial trigger 
command. After scanning the Read Time-Out bar code, set the time-out duration 
(from 0-300,000 milliseconds) by scanning digits from the Programming Chart, 
beginning on page 341, then Save. Default = 30,000 ms.