Xenon/Granit User Guide 179
Codabar
<Default All Codabar Settings>
Codabar On/Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters. Default = Don’t Trans-
mit.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can program
the scanner to read only Codabar bar codes with Modulo 16 check characters.
Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar code data
with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will only read
Codabar bar codes printed with a check character, and will transmit this character
at the end of the scanned data.
* On
Off
Transmit
* Don’t Transmit