Xenon/Granit User Guide 131
User-Specified Aimer Delay
If you want to set your own length for the duration of the delay, scan the bar code
below, then set the time-out by scanning digits (0 - 4,000 ms) from the
Programming Chart, beginning on page 341, then Save.
Aimer Mode
This feature allows you to turn the aimer on and off. When the Interlaced bar code
is scanned, the aimer is interlaced with the illumination LEDs. Default = Interlaced
Note: Granit 1980i and 1981i do not support Aimer Mode.
Centering
Use Centering to narrow the scanners field of view to make sure that when the
scanner is hand-held, it reads only those bar codes intended by the user. For
instance, if multiple codes are placed closely together, centering will insure that
only the desired codes are read. (Centering can be used in conjunction with Aimer
Delay, page 130, for the most error-free operation in applications where multiple
codes are spaced closely together. Using the Aimer Delay and Centering features,
the scanner can emulate the operation of older systems, such as linear laser bar
code scanners.)
Note: To adjust centering when the scanner is in the stand, see Presentation
Centering (page 5-121).
Delay Duration
Off
* Interlaced