184 Xenon/Granit User Guide
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
Code 39 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, scan the bar code below, select
the code page with which the bar codes were created (see ISO 2022/ISO 646
Character Replacements on page 334), and scan the value and the Save bar code
from the Programming Chart, beginning on page 341. The data characters should
then appear properly.
BEL $G ETB $W ‘/G 77 GG WW g+G w+W
BS $H
CAN $X (/H 88 HH XX h+H x+X
HT $I
EM $Y )/I 99 II YY i+I y+Y
LF $J
SUB $Z */J :/ZJJ ZZ j+J z+Z
VT $K
ESC %A +/K ;%FKK [%Kk+K {%P
FF $L
FS %B ,/L <%GLL \%Ll+L |%Q
CR $M
GS %C -- =%HMM ]%Mm+M }%R
SO $N
RS %D .. >%INN ^%Nn+N ~%S
SI $O
US %E //O ?%JOO _%Oo+O DEL %T
Full ASCII Table (Continued)
Full ASCII On
* Full ASCII Off