20 FireWarden 100-2/E — P/N 52778:A 11/04/2005
Product Description Getting Started
AFM-16AT Annunciator Fixed Module annunciates 16 zones with 16 red alarm LEDs and
16 yellow trouble LEDs. In addition, it has a System Trouble LED, an On Line/Power LED
and a local piezo sounder. It also has switches for FACP Acknowledge, Silence, Reset and
Drill. It is fixed at address ‘1.’
ACM-32A Annunciator Control Module annunciates 32 alarm zones with 32 red LEDs. In
addition, it has a System Trouble LED, an On Line/Power LED and a local piezo sounder. It
also has a switch for local piezo silence. It has rotary address switches and will accept one
AEM-32A Expander.
AEM-32A Annunciator Expander Module annunciates 32 alarm zones with 32 red LEDs
AFM-16A Annunciator Fixed Module annunciates 16 alarm zones with 16 red alarm LEDs.
In addition, it has a System Trouble LED, an On Line/Power LED and a local piezo sounder.
It also has a switch for local piezo silence. It is fixed at address ‘1.’
AFM-32A Annunciator Fixed Module annunciates 32 alarm zones with 32 red LEDs.
FDU-80 Remote Fire Annunciator
The FDU-80 annunciator is a compact 80-character backlit LCD remote fire annunciator that is
capable of displaying English language text. It mimics the display on the control panel and will
annunciate device type, point alarm, trouble or supervisory condition, zone assignment plus any
custom alpha labels programmed into the FACP. The annunciator also provides system status
LEDs to display AC Power, Alarm, Trouble, Supervisory and Alarm Silenced conditions.
Additionally, the FDU-80 is capable of remotely performing critical system functions such as
Acknowledge, Silence, Reset and Drill.
Communications between the control panel and the annunciator is accomplished over a serial
interface employing the EIA-485 communication standard. Up to 32 FDU-80 annunciators may be
connected to the EIA-485 circuit. The annunciators may be powered from the host FACP or a
remote UL listed filtered power supply such as the FCPS Series. For more detailed information,
refer to the FDU-80 manual.
LDM Series Lamp Driver Modules (Graphic Annunciator)
The LDM Series Lamp Driver Modules, which consist of the LDM-32 master and LDM-E32
expander modules, are used to provide an interface to a custom graphic LED annunciator. The
master module provides power and control for a maximum of three expander modules. The LDM-
32 and LDM-E32 have output connectors which are used to drive lamps or LEDs and input
connectors which are used for remote switch functions. Refer to the LDM Series Lamp Driver
Modules manual for a complete description.
1.9 Getting Started
The following is a brief summary of the minimal steps involved in bringing an NFW2-100 on-line:
Install Backbox and Main Circuit Board (refer to “Mounting the Backbox” on page 23)
Address and Install Intelligent Devices (refer to the FireWarden SLC Wiring Manual)
Enter Autoprogramming (refer to “Autoprogram” on page 44)
Resolve Programming Conflicts
Go to Point Program to Enter Specific Data (refer to “Point Program” on page 44). Use the
right and left arrow keys to navigate between devices.
1.10 Telephone Requirements and Warnings
1.10.1 Telephone Circuitry
Ringer Equivalence Number (REN) = 0.0B
AC Impedance: 10.0 Mega Ohm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell NOTIFIER FireWarden-100-2 and is the answer not in the manual?

Honeywell NOTIFIER FireWarden-100-2 Specifications

General IconGeneral
BrandHoneywell
ModelNOTIFIER FireWarden-100-2
CategoryFire Alarms
LanguageEnglish

Related product manuals