Appendix B - Default Settings
User Instructions for PC42d Desktop Printer 43
Default settings
Use this Appendix to check the printer’s default settings. If you had restored the printer
to its factory default values, it will use the values listed here. The settings' sequence is
similar to the layout in the printer's web page.
Serial port settings
This section explains the serial port settings. To check the settings:
On the printer web page, click Configureoption > Communications >
Serial.
Note: Unless you have installed the optional serial port on the printer and it is
connected to your PC, you will not be allowed to access the settings.
Serial port settings
Settings
Description
Default Value
Baud Rate
The serial port’s transmission speed, designated in bit per second (bps).
115200
Data Bits
The bits that define a character or byte.
8
Parity
Designates the manner in which the printer examines the integrity of
transmitted data.
None
Stop Bit
This is the bit number at the end of each character. It allows the
signal-receiving hardware to check the character’s end and resume
synchronization with the character.
1
Hardware
This checks whether the designated hardware flow-control (RTS/CTS) is
being used to manage rate of data transmission between the equipment
and main unit.
Disabled
ENQ/ACK
This checks whether the designated software flow-control (ENQ/ACK) is
being used to manage rate of data transmission between the equipment
and main unit.
Disabled
XON/XOFF to
This checks whether the designated software flow-control (XON/OFF) is
being use to manage rate of data transmission of the main unit.
Disabled
XON/XOFF from
This checks whether the designated software flow-control (XON/OFF) is
being use to manage rate of data transmission of the main unit.
Disabled
Line Feed
Character
The defines the printer’s echo to the main unit as indication that it has
moved to character in the new line.
CR/LF

Table of Contents

Other manuals for Honeywell PC42d

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell PC42d and is the answer not in the manual?

Honeywell PC42d Specifications

General IconGeneral
ColorNo
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Maximum print height- mm
Maximum printing width104 mm
Display-
Product colorBlack
Ethernet LANYes
USB 2.0 ports quantity1
Flash memory128 MB
Internal memory64 MB
Built-in barcodes1D, 2D, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Core diameter38.1 mm
Maximum label width110 mm
Maximum label length0.99 m
Maximum roll diameter128 mm
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)5 - 40 °C
Storage relative humidity (H-H)10 - 90 %
Operating relative humidity (H-H)15 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth174 mm
Width184 mm
Height222.5 mm
Weight1500 g