Chapter 3: Printer Troubleshooting and Maintenance
User Instructions for PC42d Desktop Printer 31
Changing printer head
As the printer head undergoes wear and tear as a result of rapid heating and cooling
during the printing process, you would be required to regularly replace it. The duration
between each replacement of the printer head is dependent on many factors, including
the type of images printed, the medium use, the energy volume of the printer head,
printing speed and the room temperature of the room in which the printer is situated.
When the printer is being re-activated, its firmware will check the printer head.
1. Switch off the printer and remove its power supply;
2. Open the printer’s cover by turning the handles on both sides of the printer;
3. Simultaneously turn the flexible locking mechanism on both sides of the printer
head such as to enable the printer head to move forward away from the printing
mechanism.
4. Carefully remove the printer head from the printing mechanism using a cross
screwdriver in such a way that the printer head is still be connected to it but only by
way of electric cable and ground screw;
5. Use #2 cross screwdriver to remove the ground screw.

Table of Contents

Other manuals for Honeywell PC42d

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell PC42d and is the answer not in the manual?

Honeywell PC42d Specifications

General IconGeneral
ColorNo
Print technologyDirect thermal
Maximum resolution203 x 203 DPI
Maximum print height- mm
Maximum printing width104 mm
Display-
Product colorBlack
Ethernet LANYes
USB 2.0 ports quantity1
Flash memory128 MB
Internal memory64 MB
Built-in barcodes1D, 2D, Code 49, Data Matrix, MaxiCode, MicroPDF417, PDF417, QR Code
Core diameter38.1 mm
Maximum label width110 mm
Maximum label length0.99 m
Maximum roll diameter128 mm
AC input voltage100 - 240 V
AC input frequency50 - 60 Hz
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)5 - 40 °C
Storage relative humidity (H-H)10 - 90 %
Operating relative humidity (H-H)15 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth174 mm
Width184 mm
Height222.5 mm
Weight1500 g