7 - 50
Default = Don’t Require Addenda.
EAN-13 Beginning with 977 Addenda Required
This setting programs the scanner to require a 2 digit addenda only on 
EAN-13 bar codes that begin with “977.”  The following settings can be pro-
grammed:
Require 2 Digit Addenda:  All EAN-13 bar codes that begin with “977” 
must have a 2 digit addendum.  The EAN-13 bar code with the 2 digit 
addendum is then transmitted as a single, concatenated bar code.  If a 2 
digit addendum is not found within the Addenda Timeout period, the EAN-
13 bar code is discarded.
Don’t Require 2 Digit Addenda:  If you have selected Require 2 Digit 
Addenda, and you want to disable this feature, scan Don’t Require 2 Digit 
Addenda.  EAN-13 bar codes are transmitted, depending on the setting 
you are using for EAN/JAN-13 Addenda Required.
Default = Don’t Require 2 Digit Addenda.
EAN-13 Beginning with 978 Addenda Required
These settings program the scanner to require a 5 digit addenda only on 
EAN-13 bar codes that begin with “978.”  The following settings can be pro-
grammed:
Require 2 Digit Addenda
* Don’t Require Addenda
Require 5 Digit Addenda
Require 2 or 5 Digit Addenda
Require  2 Digit Addenda
* Don’t Require  2 Digit 
Addenda