2 - 22
Character-Based Flow Control with Timeout: The scanner asserts RTS
when it has a character to send and waits for a delay (see RS232 Timeout
on page 2-22) for CTS to be asserted by the host. If the delay time expires
and CTS is not asserted, the device transmit buffer is cleared and scanning
may resume.
Default =RTS/CTS Off (Voyager 1200)
RTS/CTS Off, RTS Inactive (Voyager 1202).
RS232 Timeout
When using Flow Control with Timeout, you must program the length of the
delay you want to wait for CTS from the host. Set the length (in millisec-
onds) for a timeout by scanning the bar code below, then setting the time-
out (from 1-5100 milliseconds) by scanning digits from the Programming
Chart, then scanning Save.
Default = 1000 ms (1 second).
Flow Control, No Timeout
* RTS/CTS Off
Two-Direction Flow Control
Flow Control with Timeout
Character-Based Flow Control
with Timeout
Character-Based Flow Control,
No Timeout
* RTS/CTS Off, RTS Inactive
RS232 Timeout

Table of Contents

Other manuals for Honeywell Voyager 1202G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Voyager 1202G and is the answer not in the manual?

Honeywell Voyager 1202G Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor typeLaser
Scanner type1D
Pitch reading angle60 - 60 °
Linear (1D) barcodes supported-
Wireless range10 m
Bluetooth version2.1+EDR
Operating frequency2.4 - 2.5 MHz
Standard interfacesBluetooth
Connectivity technologyWireless
Battery life12 h
Charging time4 h
Input voltage5 V
Battery capacity1800 mAh
Power source typeBattery
Number of reads per charge45000
Product colorBlack
International Protection (IP) codeIP42
Storage temperature (T-T)-5 - 35 °C
Operating temperature (T-T)5 - 40 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth180 mm
Width66 mm
Height92 mm
Weight180 g
Base weight185 g
Base dimensions200 x 67 x 97 mm