Loading...
7 - 57
scanning the bar code below, then setting the timeout (from 0-65535 milli-
seconds) by scanning digits from the Programming Chart, then scanning
Save.
Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon
code searches.
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the bar
code and the data from the addenda. When turned Off, there is no space.
Default = Off.
EAN/JAN-8 Redundancy
If you are encountering errors when reading EAN/JAN-8 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the ba code. To adjust the redundancy, scan the
EAN/JAN-8 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the Programming Chart inside the back cover of this
manual. Then scan the Save bar code.
Default = 0.
Addenda Timeout
* Off
On
EAN/JAN-8 Redundancy