Vuquest 3320g User Guide 93
Codabar
<Default All Codabar Settings>
Codabar On/Off
Codabar Start /Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You 
may either transmit, or not transmit Start/Stop characters.  Default = Don’t Trans-
mit.
Codabar Check Character
Codabar check characters are created using different “modulos.”  You can program 
the scanner to read only Codabar bar codes with Modulo 16 check characters.  
Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar code data 
with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will only read 
Codabar bar codes printed with a check character, and will transmit this character 
at the end of the scanned data.