EasyManua.ls Logo

Honeywell Vuquest 3330 - Codabar; Codabar On;Off; Codabar Start;Stop Characters; Codabar Check Character

Honeywell Vuquest 3330
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Vuquest 3320g User Guide 93
Codabar
<Default All Codabar Settings>
Codabar On/Off
Codabar Start /Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters. Default = Don’t Trans-
mit.
Codabar Check Character
Codabar check characters are created using different “modulos.” You can program
the scanner to read only Codabar bar codes with Modulo 16 check characters.
Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar code data
with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will only read
Codabar bar codes printed with a check character, and will transmit this character
at the end of the scanned data.
* On
Off
Transmit
* Don’t Transmit

Table of Contents

Related product manuals