26 Vuquest 3320g User Guide
RS232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an application
requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctua-
tion), select 7 data bits. For applications that require use of the full ASCII set, select
8 data bits per character. Default = 8.
300
600
1200
2400
4800
9600
19200
38400
57,600
* 115,200

Table of Contents