EasyManua.ls Logo

HP 10504 - Table of Contents

HP 10504
121 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
i
Contents
Preparing for installation ············································································································································· 1
Safety recommendations ·················································································································································· 1
General safety recommendations ··························································································································· 1
Electricity safety ························································································································································ 1
Handling safety ························································································································································ 2
ESD prevention ························································································································································· 2
Laser safety ································································································································································ 2
Examining the installation site ········································································································································· 2
Weight support ························································································································································· 2
Temperature ······························································································································································ 3
Humidity ···································································································································································· 3
Cleanness ·································································································································································· 3
EMI ············································································································································································· 4
Grounding ································································································································································· 4
Power ········································································································································································· 4
Cooling ······································································································································································ 5
Space ········································································································································································· 6
Tools and equipment ························································································································································ 6
Installing the switch ······················································································································································ 8
Confirming installation preparations ······························································································································· 8
Installing the switch in a 19-inch rack ····························································································································· 8
Attaching slide rails and cage nuts to the rack ····································································································· 8
Installing mounting brackets and cable management brackets ········································································ 13
Mounting the switch in the rack ··························································································································· 16
Mounting the switch on a workbench or floor ············································································································ 17
Installation preparation ········································································································································· 17
Installation procedures ·········································································································································· 17
Grounding the switch ···················································································································································· 18
Grounding the switch with a grounding strip ····································································································· 18
Grounding the switch through the PE wire of an AC power supply ································································ 19
Grounding the switch through the RTN wire of a DC power supply ······························································· 20
Installing FRUs ···························································································································································· 21
Attaching an ESD wrist strap ········································································································································ 21
Installing MPUs/LPUs/switching fabric modules ········································································································ 22
Installing a power supply ·············································································································································· 23
Connecting the power cord ·········································································································································· 26
Connecting an AC power cord ··························································································································· 26
Connecting a DC power cord ······························································································································ 27
Installing a transceiver module (optional) ···················································································································· 28
Installing an XFP/SFP+/SFP/QSFP+ module ····································································································· 28
Installing a CFP module ········································································································································ 29
Connecting an SFP+/QSFP+/QSFP+ to SFP+ cable ································································································· 29
Setting up an IRF fabric ············································································································································· 31
IRF fabric setup flowchart ·············································································································································· 31
Planning IRF fabric setup ··············································································································································· 32
Planning IRF fabric size and the installation site ································································································ 32
Identifying the master switch and planning IRF member IDs ············································································ 33

Table of Contents

Related product manuals