Residual
FM
Performance
Test
Configure the
HP
1.
Turn modulation
off
press
[MOD
ONIOFF].
8647A
2.
Set the amplitude; press @
1-0.
3.
Turn the
RF
output on; press
c-).
Measure Deviations
1.
Enter the frequencies shown in the test record.
2.
Record the test results and compare the results
to
the limits in the
test record.
Note
The voltage displayed
by
the audio analyzer can be read
as
Hz.
For
example,
10
mV equals
10
Hz.
Performance
Tests
8-13