HP BladeSystem Insight Display 68
o
Yes—Copy the configured power settings, rack name, and LCD Lockout PIN (if set) from the
Enclosure Settings screen to the detected enclosures.
o NoContinue configuring the current enclosure only. The Insight Display installation wizard must
be run on each of the other detected enclosures. Select this option if each enclosure requires
different power settings.
IMPORTANT: If your facility uses Static IP addressing for the Onboard Administrator modules,
you must manually enter those IP addresses into the Insight Display for each Insight Display
sepa
rately. You can enter those Onboard Administrator module IP addresses before you send the
settings to adjacent enclosures. You can return to the Enclosure Settings menu after the Installation
Wizard completes to change the Onboard Administrator module IP addresses, if necessary.
7. Navigate the cursor to Accept, and press the OK button.
The Check: Installation and Cables screen appears.
8. Verify all components are installed and cabled before continuing.
9. Select Continue, and press the OK button to begin checking for configuration and installation errors.
The enclosure UID automatically turns off. If Push Settings = Yes:
o The enclosure settings are pushed to adjacent enclosures
o The installation wizards run on each adjacent enclosure
o The enclosure UID turns off on the adjacent enclosures

Table of Contents

Other manuals for HP BladeSystem c7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP BladeSystem c7000 and is the answer not in the manual?

HP BladeSystem c7000 Specifications

General IconGeneral
Form Factor10U
Number of Bays16
Redundant PowerYes
Redundant FansYes
Maximum Blade Servers16 half-height or 8 full-height
Operating Temperature10° to 35°C (50° to 95°F)
Power SuppliesUp to 6
Cooling Fans10
ManagementOnboard Administrator
Interconnect ModulesUp to 8
Networking OptionsEthernet, Fibre Channel, InfiniBand
CompatibilityHP ProLiant and Integrity server blades
Relative Humidity10% to 90% (non-condensing)