3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
• Extend the server from the rack.
• Remove the server from the rack.
5. Remove the access panel.
6. Remove the air baffle.
7. Disconnect all cables from the LFF NVMe drive backplane.
8. Remove the LFF NVMe drive cage.
To replace the component, reverse the removal procedure.
Removing and replacing the LFF NVMe drive backplane
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1. If installed, remove the front bezel.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
78 Removal and replacement procedures